17 MARCH 2020
This is an update for Cora SeQuence V8.8, which includes a fix to a product issue.
Resolved issue
Component | Issue | Ticket # |
---|---|---|
Hot Operations | The Execute Plan Built-In Command did not work properly in specific scenarios. | 81845 |
Update steps
Updating from V8.8.1.1.
- Back up your Cora SeQuence database.
- Back up the following files:
- In the Administration site,
bin\PNMsoft.Sequence.Studio.dll
. - In all servers, in the GAC,
PNMsoft.Sequence.HotOperations.dll
.
- In the Administration site,
NOTE
Make sure that you save the backed up files in a different folder, such as the desktop.
- Download the ZIP file.
- Open the DB Scripts folder, and run the following script on your Cora SeQuence database:
PatchSynchronization_Data.sql
- Make sure the following files and folders are in the same level on the server.
Engine
SequencePatch.xml
SequencePatcher.ps1
- Right click
SequencePatcher.ps1
, and then select Run with PowerShell.
Rollback steps
- Restore the Cora SeQuence database to previous state.
- Restore the backed up files.
NOTE
If you are running a Cora SeQuence version earlier than V8.8.1.1, you need to install V8.8.1.1 before you install V8.8.1.2.